Yeadagroup (China) limited
Language: 中文版 English
Products search
  • Home
  • About us
  • Products
    • Gas purification systems
    • Glovebox Industry applications&Solutions
    • Feedthroughs & Viewports
    • Glovebox Accessories
    • Plasma/UV-Zone Cleaners
    • Ultrasonics/Water Circulator
    • Film Coating
    • Electronic Packages
    • Battery R&D Equipment
    • R2R Flexible Electronics Printing
  • News
    • Company news
    • Industry news
    • Glove box chemical applications
    • Glove box pharmaceutical applications
    • Glove box battery application
    • Glove box nuclear energy applications
    • Glove box OLED / PLED / OPV applications
    • Glove box welding applications
    • Glove box lighting applications
  • Download
    • Help document
    • File download
  • Photo
    • Product pictures
    • Customer Case
  • Feedback
  • Inquiry
  • Contact us

NAVIGATION

  • Inert Gas GLovebox
    • Single-Side Operation
    • Double-Side Operation
    • Custom Glovebox
    • Vacuum glove box
    • Acrylicglovebox
  • Gas purification systems
    • Standard gas purification system
    • Metal 3D printing inert gas purification systems
    • Negative pressure inert gas purification systems
    • Explosion-proof inert gas purification systems
    • Argon Gas Purifier
  • Glovebox Industry applications&Solutions
    • Product protection
    • Operator protection
    • Inert gas welding protection
    • Nuclear-Energy Bio and Medicine Glovebox
    • Metal 3D Printer
  • Feedthroughs & Viewports
  • Glovebox Accessories
    • Glovebox Analyzer
    • Glovebox Vacuum Accessories
    • Vacuum Pump
    • Vacuum Ovens 200-500℃
    • Security products
    • Glove and Glove Port
    • Compressed Gas Regulators
    • Antechamber&Accessories
  • Plasma/UV-Zone Cleaners
  • Ultrasonics/Water Circulator
  • Film Coating
    • Spin Coater
    • Thermal Evaporators
  • Electronic Packages
  • Battery R&D Equipment
    • Programme of super capacitor
    • Equipment for Film Solar Cell
    • Organic thin-film solar cell
    • Solid Li-Ion Battery Research
    • Button Cell Preparation
    • Battery Test Equipment
    • Crimping Machine
  • R2R Flexible Electronics Printing

LATEST NEWS

  • Made in Space – 1st ISS 3D Printer
  • M-Braun Glovebox System Operation Procedur
  • Stainless steel glove box
  • NREL test helps make moisture barriers bet
  • Organic/inorganic sulfur may be key for sa
  • Grant supports development of next-generat

CONTACT US

  • Add: RM 1802B-A6 Fortress Tower 250 Kings RD North Point HongKong
  • Tel: +86 010 8499 8901
  • Fax: +86 010 8499 8901
  • Email: adahan@foxmail.com

ONLINE STORE

Your position: Home > Glovebox Analyzer
Glovebox Process oxygen analyzer EC913
Left
  • Glovebox Process oxygen analyzer EC913
Right

Glovebox Process oxygen analyzer EC913

  • Product description: Glovebox Process oxygen analyzer EC913
  • Inquiry

Product introduction

Picture

Technical specifications

Sensor Type:RaceTM

Ranges:0.1PPM~30%

Accuracy:±2%

Response:20ppm<2min

Sample Inlet Pressure:0.25-2Barg,3-30psi

Sample Flow Rate :Approximately 140cc/min

Sample Temperature:-5 to 50℃

Ambient Temperature:-5 to 50℃,RH 0-99% non-condensing

Sample Connections:1/8O∥D Compression fittings,as standard

Communications:USB/RS485

Power Supply:110/230VAC selectable

Display Type:4 digit high visibility LED

Options

High/Low Alarm:2 Volt free changeover contacts,Rated 240V 3A

Analogue Outputs:3 Analogue output channels 4-20mA(0-20mA),0-10V,0-100mV,all isolated

Autocalibrate:Provision for remote cal start and autocal in progress

Sample Stream Options:Bypass flowmeter,sample Pump,flow alarm,stainless steel sample system in place of brass/copper

Nitrosave Ex Proof:O2 measurement and control system EC9500

Specification

Industry:Process

Gas:Oxygen

Application:Industrial Gas、Glove Boxes

Measuring cell type: :Electrochemical: Percentage, trace and RACE cell

Measurement range:Trace 0.1ppm - 1%. RACE邃「 0.1ppm - 30%. Percent 0.3% - 100%

Response Time:Trace 90% within 30 sec. RACE™ Air to 20ppm within 2 min. Percent 90% within 30 sec.

Unsuitable gases:Acid gases, corrosives and solvents in significant concentration

Features&Benefits

Long life, maintenance-free disposable oxygen sensor

Ambient air or traceable gas calibration

Microprocessor controlled functions

Large, autoranging LED display

Fast response. Ultra fast response version

Unaffected by vibration or position

Sturdy, reliable construction with three sensor options

Specific to oxygen measurement

Insensitive to sample flow rate - percentage through ppm

Nitrosave flushing gas control option EC9500

The EC900 has a 36 month warranty which covers any faulty workmanship and normal component failure relating to electronic circuit cards

Applications

Chemical/Petrochemical - Chemical production, High purity gas production, Hydrocarbon refining, Natural gas transmission

Curing - Electron beam, Ultraviolet

Electronics - Reflow/wave soldering, Solder powder production, Semiconductor furnaces, Gas quality

Metals - Heat treating/Annealing, Steel production, Alloys and powdered metals

Pharmaceutical - Inert packaging, Vessel blanketing, Fermentation

Process - Ceramics, Combustion analysis, Contact lens manufacturing, Food packaging, Glass fibre optics, Inert gas welding, Lamp manufacturing

General - Controlled environments, R&D, Glove boxes, Oxygen deficiency

PREVIOUS:Glovebox Dew Point Meter Model LPDT NEXT:Glovebox DF-130E Cost Effective Oxygen Analyz

Related products

  • oxy.IQ Galvanic Fuel Cell Oxygen (O2) Transmitter

    oxy.IQ Galvanic Fuel Cell

    oxy.IQ Galvanic Fuel Cell Oxygen (O2) Transmitter...

  • Ge veridri moisture transmitter

    Ge veridri moisture transm

    Ge veridri moisture transmitter...

  • GE OXY.IQ_OX-1_OX-3_OX-5

    GE OXY.IQ_OX-1_OX-3_OX-5

    GE OXY.IQ_OX-1_OX-3_OX-5...

CopyRight 2016 All Right Reserved YEADAGROUP  Sitemap

Add: RM 1802B-A6 Fortress Tower 250 Kings RD North Point HongKong  Tel: +86 010 8499 8901  Fax: +86 010 8499 8901