儀達集團(中國)有限公司
語言選著: 繁體版 English
產品搜索
  • 網站首頁
  • 公司簡介
  • 產品中心
    • 氣體淨化系統
    • 手套箱解決方案
    • Feedthroughs & Viewports
    • 手套箱配件
    • Plasma/UV-Zone Cleaners
    • Ultrasonics/Water Circulator
    • Film Coating
    • Electronic Packages
    • Battery R&D Equipment
    • R2R Flexible Electronics Printing
  • 新聞中心
    • 公司新聞
    • 行業新聞
    • Glove box chemical applications
    • Glove box pharmaceutical applications
    • Glove box battery application
    • Glove box nuclear energy applications
    • Glove box OLED / PLED / OPV applications
    • Glove box welding applications
    • Glove box lighting applications
  • 下載中心
    • 幫助文檔
    • 檔案下載
  • 公司相冊
    • 產品圖片
    • 客戶案例
  • 在線留言
  • 在線訂購
  • 聯繫我們


欄目導航

  • 惰性氣體保護手套箱
    • 單面惰性氣體保護手套箱
    • 雙面惰性氣體保護手套箱
    • 非標定制手套箱
    • Vacuum glove box
    • Acrylicglovebox
  • 氣體淨化系統
    • 標準氣體淨化系統
    • 金屬3D打印惰性氣體淨化系統
    • 負壓型惰性氣體淨化系統
    • 防爆型惰性氣體淨化系統
    • 氬氣淨化器/淨化系統
  • 手套箱解決方案
    • 產品保護
    • 操作人員保護
    • 惰性氣體焊接保護
    • 核能生化及醫藥手套箱
    • 金屬3D打印(列印)
  • Feedthroughs & Viewports
  • 手套箱配件
    • 手套箱分析儀
    • 手套箱真空配件
    • 真空泵及备件
    • 真空烘箱200-500度
    • 安全產品
    • 手套和手套口等配件
    • 氣體壓力
    • 過度艙及配件
  • Plasma/UV-Zone Cleaners
  • Ultrasonics/Water Circulator
  • Film Coating
    • Spin Coater
    • Thermal Evaporators
  • Electronic Packages
  • Battery R&D Equipment
    • 鋰電池及超級電容方案
    • 鈣鈦礦太陽能電池製備
    • 有機薄膜太陽能電池
    • 固態鋰電池
    • 扣式電池製備
    • Battery Test Equipment
    • 切片/封口机
  • R2R Flexible Electronics Printing


新聞中心

  • Made in Space – 1st
  • M-Braun Glovebox Sys
  • 不鏽鋼手套箱
  • NREL test helps make
  • Organic/inorganic su
  • Grant supports devel

联系我们

  • 地址:RM 1802B-A6 Fortress Tower 250 Kings RD North Point HongKong
  • 电话:+86 010 8499 8901
  • 传真:+86 010 8499 8901
  • 邮箱:adahan@foxmail.com

网上商店

您現在的位置:網站首頁 > 手套箱分析儀
AMI 2001 series Trace Oxygen Analyzer
Left
  • AMI 2001 series Trace Oxygen Analyzer
  • AMI 2001 series Trace Oxygen Analyzer
  • AMI 2001 series Trace Oxygen Analyzer
  • AMI 2001 series Trace Oxygen Analyzer
Right

AMI 2001 series Trace Oxygen Analyzer

  • 产品描述:AMI 2001 series Trace Oxygen Analyzer,Glovebox;
  • 在线订购

产品介绍

Model

Description

Content

MODEL 2001RS

Picture

Overview

- Display reads oxygen from 0.05ppm up to 25.0% with no range changes

- Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution

- Analog output 4-20mA, isolated.

- Complete sample system built into AMI’s patented cell block.

- Very rapid response time from air to low ppm levels.

- Easily replaceable sensor, no tools required.

- T-2 sensor resistant up to 10ppm H2S.

- Simple, versatile installation.

- Operates off 117VAC with very low power consumption

- Analog output can be easily calibrated to an external device.

- 2 independent, fully adjustable alarm settings with relay contacts.

- Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off.

- Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc.

- USB connectivity to a PC: Allows complete access to the internal functions and settings.

- ModBus Industry standard protocol over RS485.

- Oxygen Sensor life indication.

- Calibration history.

Feature

- 10 user selectable output ranges

- 3 1/2 digit LCD

- 2 fully adjustable oxygen concentration alarms

- Alarm hold off/Bypass

- RFI protected

- 4-20mA. isolated analog output

- Analog output calibration synchronizes the analog output with an external monitoring system

- Data logger

- Fully programmable alarm delays

- USB port for configuration and access to advanced features

- Calibration history and sensor usage logging

- Power brownout and power failure logging

- Modbus using Bidirectional RS485 for industry-standard communications

- Low minimum detection limit 0.05ppm

- Excellent repeatability

- Extended operating temperature range

- Fast upscale/downscale response times

- Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings.

- Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools.

- Unaffected by changes in flow rate from 0.1 to 2.0 SCFH

- Panel mount

- Compact size

- 2 year warranty for analyzer, parts and labor

- 6 month sensor warranty, life expectancy 1-2 years

- Requires optional AMI User Interface software

Specifications

- 2001R Series Standard ranges:

- 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25%

- Sensitivity: 0.5% of full scale

- Repeatability: +/- 1% of full scale at constant temperature

- Operating temperature: 41°F to 113°F.

- Maximum inlet pressure: 20psig

- Humidity: < 85%, non-condensing

- Operational conditions: Pollution degree 2, Installation category I I.

- Drift: +/- 1% of full scale in 4 weeks at constant temperature

- Expected cell life: 9 months to 2 years.

- Response times (dependent on sensor):

- 90% of full scale in less than:

- 0 – 10 ppm 25 sec

- 0 – 100 ppm 10 sec

- 0 – 1000 ppm 10 sec

- Outputs: 4-20mA isolated.

- Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive

- Datalogger: Logs data for 15 days @ 1 minute intervals; 30 days @ 2 minute intervals, etc. Represents the output range selected: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 25%. Overange capability up to ten times the range selected.

- Power requirements: 90-240VAC <10W.

- Absolute Maximum Power voltage 264VAC 60Hz.

- ¼” Stainless Steel compression fittings for sample, span gas and exhaust.

- Overall dimensions: 9” w x 5” h x 7” d

- Weight 10 lbs

MODEL 2001RSP

Picture

Overview

- Display reads oxygen from 0.05ppm up to 25.0% with no range changes

- Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution

- Analog output 4-20mA, isolated.

- Complete sample system built into AMI’s patented cell block.

- Very rapid response time from air to low ppm levels.

- Easily replaceable sensor, no tools required.

- T-2 sensor resistant up to 10ppm H2S.

- Simple, versatile installation.

- Operates off 117VAC with very low power consumption

- Analog output can be easily calibrated to an external device.

- 2 independent, fully adjustable alarm settings with relay contacts.

- Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off.

- Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc.

- USB connectivity to a PC: Allows complete access to the internal functions and settings.

- ModBus Industry standard protocol over RS485.

- Oxygen Sensor life indication.

- Calibration history.

Feature

- 10 user selectable output ranges

- 3 1/2 digit LCD

- 2 fully adjustable oxygen concentration alarms

- Alarm hold off/Bypass

- RFI protected

- 4-20mA. isolated analog output

- Analog output calibration synchronizes the analog output with an external monitoring system

- Data logger

- Fully programmable alarm delays

- USB port for configuration and access to advanced features

- Calibration history and sensor usage logging

- Power brownout and power failure logging

- Modbus using Bidirectional RS485 for industry-standard communications

- Low minimum detection limit 0.05ppm

- Excellent repeatability

- Extended operating temperature range

- Fast upscale/downscale response times

- Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings.

- Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools.

- Unaffected by changes in flow rate from 0.1 to 2.0 SCFH

- Panel mount

- Compact size

- 2 year warranty for analyzer, parts and labor

- 6 month sensor warranty, life expectancy 1-2 years

- Requires optional AMI User Interface software

Specifications

- 2001R Series Standard ranges:

- 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25%

- Sensitivity: 0.5% of full scale

- Repeatability: +/- 1% of full scale at constant temperature

- Operating temperature: 41°F to 113°F.

- Maximum inlet pressure: 20psig

- Humidity: < 85%, non-condensing

- Operational conditions: Pollution degree 2, Installation category I I.

- Drift: +/- 1% of full scale in 4 weeks at constant temperature

- Expected cell life: 9 months to 2 years.

- Response times (dependent on sensor):

- 90% of full scale in less than:

- 0 – 10 ppm 25 sec

- 0 – 100 ppm 10 sec

- 0 – 1000 ppm 10 sec

- Outputs: 4-20mA isolated.

- Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive

- Datalogger: Logs data for 15 days @ 1 minute intervals; 30 days @ 2 minute intervals, etc. Represents the output range selected: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 25%. Overange capability up to ten times the range selected.

- Power requirements: 90-240VAC <10W.

- Absolute Maximum Power voltage 264VAC 60Hz.

- ¼” Stainless Steel compression fittings for sample, span gas and exhaust.

- Overall dimensions: 9” w x 5” h x 7” d

- Weight 10 lbs

MODEL 2001RSM

Picture

Overview

- Display reads oxygen from 0.05ppm up to 25.0% with no range changes

- Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution

- Analog output 4-20mA, isolated.

- Complete sample system built into AMI’s patented cell block.

- Scans through up to five sample inputs, or may be set to dwell on any of them.

- Very rapid response time from air to low ppm levels.

- Easily replaceable sensor, no tools required.

- T-2 sensor resistant up to 10ppm H2S.

- Simple, versatile installation.

- Operates off 117VAC with very low power consumption

- Analog output can be easily calibrated to an external device.

- 2 independent, fully adjustable alarm settings with relay contacts.

- Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off.

- Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc.

- USB connectivity to a PC: Allows complete access to the internal functions and settings.

- ModBus Industry standard protocol over RS485.

- Oxygen Sensor life indication.

Feature

- Built-in sample channel sequencer with up to 5 input channels.

- 10 user selectable output ranges

- 3 1/2 digit LCD

- 2 fully adjustable oxygen concentration alarms

- Alarm hold off/Bypass

- RFI protected

- 4-20mA. isolated analog output

- Analog output calibration synchronizes the analog output with an external monitoring system

- Data logger

- USB port for configuration and access to advanced features

- Calibration history and sensor usage logging

- Power brownout and power failure logging

- Modbus using Bidirectional RS485 for industry-standard communications

- Low minimum detection limit 0.05ppm

- Excellent repeatability

- Extended operating temperature range

- Fast upscale/downscale response times

- Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings.

- Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools.

- Unaffected by changes in flow rate from 0.1 to 2.0 SCFH

- Panel mount

- Compact size

- 2 year warranty for analyzer, parts and labor

- 6 month sensor warranty, life expectancy 1-2 years

- Requires optional AMI User Interface software

Specifications

- 2001R Series Standard ranges:

- 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25%

- Sensitivity: 0.5% of full scale

- Repeatability: +/- 1% of full scale at constant temperature

- Operating temperature: 41°F to 113°F.

- Maximum inlet pressure: 20psig

- Humidity: < 85%, non-condensing

- Operational conditions: Pollution degree 2, Installation category I I.

- Drift: +/- 1% of full scale in 4 weeks at constant temperature

- Expected cell life: 9 months to 2 years.

- Response times (dependent on sensor):

- 90% of full scale in less than:

- 0 – 10 ppm 25 sec

- 0 – 100 ppm 10 sec

- 0 – 1000 ppm 10 sec

- Outputs: 4-20mA isolated.

- Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive

- Power requirements: 90-240VAC <10W.

- Absolute Maximum Power voltage 264VAC 60Hz.

- Overall dimensions: 9” w x 5” h x 7” d

- Weight 10 lbs

MODEL 2001RSPM

Picture

Overview

- Display reads oxygen from 0.05ppm up to 25.0% with no range changes

- Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution

- Analog output 4-20mA, isolated.

- Complete sample system built into AMI’s patented cell block.

- Scans through up to five sample inputs, or may be set to dwell on any of them.

- Very rapid response time from air to low ppm levels.

- Easily replaceable sensor, no tools required.

- T-2 sensor resistant up to 10ppm H2S.

- Simple, versatile installation.

- Operates off 117VAC with very low power consumption

- Analog output can be easily calibrated to an external device.

- 2 independent, fully adjustable alarm settings with relay contacts.

- Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off.

- Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc.

- USB connectivity to a PC: Allows complete access to the internal functions and settings.

- ModBus Industry standard protocol over RS485.

- Oxygen Sensor life indication.

Feature

- Built-in sample channel sequencer with up to 5 input channels.

- 10 user selectable output ranges

- 3 1/2 digit LCD

- 2 fully adjustable oxygen concentration alarms

- Alarm hold off/Bypass

- RFI protected

- 4-20mA. isolated analog output

- Analog output calibration synchronizes the analog output with an external monitoring system

- Data logger

- USB port for configuration and access to advanced features

- Calibration history and sensor usage logging

- Power brownout and power failure logging

- Modbus using Bidirectional RS485 for industry-standard communications

- Low minimum detection limit 0.05ppm

- Excellent repeatability

- Extended operating temperature range

- Fast upscale/downscale response times

- Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings.

- Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools.

- Unaffected by changes in flow rate from 0.1 to 2.0 SCFH

- Panel mount

- Compact size

- 2 year warranty for analyzer, parts and labor

- 6 month sensor warranty, life expectancy 1-2 years

- Requires optional AMI User Interface software

Specifications

- 2001R Series Standard ranges:

- 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25%

- Sensitivity: 0.5% of full scale

- Repeatability: +/- 1% of full scale at constant temperature

- Operating temperature: 41°F to 113°F.

- Maximum inlet pressure: 20psig

- Humidity: < 85%, non-condensing

- Operational conditions: Pollution degree 2, Installation category I I.

- Drift: +/- 1% of full scale in 4 weeks at constant temperature

- Expected cell life: 9 months to 2 years.

上一个:高精度濕度控制器YD-RH-606B 下一个:NATURAL RUBBER ARM GUARDS

相关产品

  • 美國GE OXY-IQ GE氧分析儀

    美國GE OXY-IQ

    美國GE OXY-IQ GE氧分析儀...

  • GE 露點變送器 Veridri

    GE 露點變送器 Ver

    GE 露點變送器 Veridri...

  • GE OXY.IQ氧电池OX-1_OX-3_OX-5电化学氧气传感器

    GE OXY.IQ氧电池

    GE OXY.IQ氧电池OX-1_OX-3_OX-5电化学氧气传感器...

CopyRight 2016 All Right Reserved 儀達集團  網站地圖

地址:RM 1802B-A6 Fortress Tower 250 Kings RD North Point HongKong  電話:+86 010 8499 8901  傳真:+86 010 8499 8901